HomeContactsRequestsDownloadsSearchNewsletterSitemap
DE
MARKETSPRODUCTSABOUT USInvestorsNewsSales ContactsJobsMedia centre
RF product search
Radio Frequency
RF Connectors
Product Groups
Adaptors
Series / Specifications
1.0/2.3
7/16
ARC (FAKRA/USCAR)
BMA
BNC connector 50 Ohm
BNC 75
BNC 75 HDTV
BNO
BNT
MCX 50
MCX 75
MHV
MMBX
MMCX
Technical data
MMPX
N 50
N 75
PC 3.5
QLA 00
QMA
QMA waterproof
QN
QUICK-FIT
SHV
SK
SMA connector
SMB
SMC
SMPX
SMS
TNC 50
TNC 75
TNCA 50
Packaging
Quick Lock Formula
Polycon DIN 7/16
Tools
Accessories
Knowledge base
Reverse polarity Connectors
Hermetically sealed connectors
RF Cables
RF Cable Assemblies
Wireless Ethernet Bridge
Antennas
Lightning / EMP Protectors
RF Power Splitters
RF Power Switch
RF Components
RF General Info
Fiber Optics
Low Frequency
Product Search
Products » Radio Frequency » RF Connectors » Product Groups » Series / Specifications » MMCX » Technical data

Print viewTechnical data of MMCX connectors

Electrical data CECC 22000 Requirements
Impedance   50
Frequency range   DC ... 6 GHz
RF-leakage*
- conn. for flex. cab.

4.4.8

60 dB
- conn. for semi-rigid cab. 4.4.8 70 dB

*measured at 1 GHz

Typical VSWR Frequency range      
Connector type 1 GHz 2.5 GHz 6 GHz Cab. Group
straight connectors 1.03 1.08 1.22 Y3, Y11
  1.04 1.08 1.22 U1
right angle connectors 1.03 1.08 1.23 Y3, Y11
  1.07 1.22 1.25 U1

Other connectors and cables upon request

Mechanical data CECC 22000 Test requirements
Engagement force 4.5.4 15 N / 3.4 lbs
Disengagement force 4.5.4 6 N ... 15 N / 1.4 lbs ... 3.4 lbs
Contact captivation 4.5.2 10 N / 2.3 lbs
Durability (matings) 4.7.1 500

Environmental data Equivalent MIL test conditions
Temperature range -55°C ... +155°C / - 67° F ... + 311° F

Material data    
Connector part Material Plating
Bodies, crimp ferrules brass SUCOPRO/gold
Centre contacts copper-beryllium-alloy / bronze SUCOPRO/gold
Insulators PTFE or PFA  

Some connectors may feature specifications that differ from the above mentioned data.

The products are designed and guaranteed to pass the above mentioned test procedures. Any additional or different requirement arising from specific applications or environmental conditions which is not covered by these test procedures is subject to request.