| Item details | |
| Item description | K_02359_30 | |
 |
| Description | Triax - FEP - 30 Ohm |
| Item number | 22511287 |
| 2002/95/EC (RoHS) | compliant |
| Data sheet |
|
| Phase | Production | | | |
 |
| Cable design | Jump to [Top] |
|
| | Material | Detail | Diameter |
| Centre conductor | Copper, Silver plated | Strand | 1 | mm |
| Dielectric | FEP | | 1.85 | mm |
| Outer conductor | Copper, Silver plated | Braid - 89% coverage | 2.3 | mm |
| Jacket | FEP | RAL 9010 - wh | 3.1 | mm |
| Jacket 2 | FEP | | 4.4 | mm |
| Tolerance jacket 2 | | | ± 0.2 | mm |
 |
| Electrical data | Jump to [Top] |
| Operating Frequency | | ≤ 0.85 | GHz |
| Nom. attenuation | Values and graph see below | Coefficient a | 0.493 | |
| | | Coefficient b | 0.94 | |
| CW Power | Values and graph see below | | | |
| Impedance | | 30 ± 2 | Ω |
| Capacitance | | 175 | pF/m |
| Propagation Velocity | | 67 | %of c |
| Signal Delay | | 5 | ns/m |
| Insulation Resist | | >100000000 | MΩm |
| Test Voltage | | 5 | kVrms |
| Operating Voltage | at sea level | 2.5 | kVrms |
 |
| General data | Jump to [Top] |
| Operating Temp min | | | -40 | °C |
| Operating Temp max | | | 165 | °C |
| Installation Temp min | | | -20 | °C |
| Installation Temp min | | | 60 | °C |
| Flame propagation | Fire Test a | | IEC 60332-1 | |
| Weight | | 3.22 | kg/100m |
| Static Bend Radius | | | 40 | mm |
| Repeated Bend Radius | | | 80 | mm |
 |
| Suitable connectors, grounding kits and installation material | Jump to [Top] |
 |
| Nominal attenuation and power | Jump to [Top] |
 |  |  |  |  | | Frequency | Attenuation* | Power** | Attenuation and power graph | | [GHz] | [dB/m] | [dB/ft] | [W] | | | 0.01 | 0.06 | 0.02 | 1250 | | 0.05 | 0.16 | 0.05 | 559 | | 0.10 | 0.25 | 0.08 | 395 | | 0.15 | 0.33 | 0.10 | 323 | | 0.20 | 0.41 | 0.12 | 280 | | 0.30 | 0.55 | 0.17 | 228 | | 0.40 | 0.69 | 0.21 | 198 | | 0.45 | 0.75 | 0.23 | 186 | | 0.50 | 0.82 | 0.25 | 177 | | 0.60 | 0.95 | 0.29 | 161 | | 0.80 | 1.19 | 0.36 | 140 | | 0.85 | 1.25 | 0.38 | 136 | | | | |
|
 |
| Please note: | Attenuation values at +25°C ambient temperature and sea level * Power values at +40°C ambient temperature and sea level ** |
| Required plug-in: | To see the 'Attenuation and power graph' the Adobe SVG Viewer version 3.0 or higher must be installed. |
 |
| Tests | Jump to [Top] |
| Following tests have been passed successfully. For any details please contact your nearest HUBER+SUHNER representative. |
| Test description | Specification / Paragraph / Method |
| Fire Test a | IEC 60332-1 |