| Item details | |
| Item description | RG_108_A/U | |
 |
| Description | Twinax - PE - 78 Ohm |
| Item number | 22510031 |
| 2002/95/EC (RoHS) | compliant |
| Data sheet |
|
| Phase | Production | | | |
 |
| Cable design | Jump to [Top] |
|
| | Material | Detail | Diameter |
| Outer conductor | Copper, Tin plated | Braid - 88% coverage | 4.6 | mm |
| Jacket | PVC II (non migration) | RAL 9005 - bk | 6 | mm |
 |
| Electrical data | Jump to [Top] |
| Operating Frequency | | ≤ 1 | GHz |
| Impedance | | 78 ± 7 | Ω |
| Capacitance | | 65 | pF/m |
| Propagation Velocity | | 66 | %of c |
| Signal Delay | | 5 | ns/m |
| Insulation Resist | | >100000000 | MΩm |
| Test Voltage | | 2 | kVrms |
| Operating Voltage | at sea level | 1 | kVrms |
 |
| General data | Jump to [Top] |
| Operating Temp min | | | -40 | °C |
| Operating Temp max | | | 85 | °C |
| Installation Temp min | | | -20 | °C |
| Installation Temp min | | | 70 | °C |
| Weight | | 4.9 | kg/100m |
| Static Bend Radius | | | 30 | mm |
| Repeated Bend Radius | | | 60 | mm |
 |
| Suitable connectors, grounding kits and installation material | Jump to [Top] |
| Cable groups | For details refer to the online coaxial connector catalogue or contact your nearest HUBER+SUHNER representative | Cable Group 1
| on request
| |
 |
| Tests | Jump to [Top] |
| Following tests have been passed successfully. For any details please contact your nearest HUBER+SUHNER representative. |
| Test description | Specification / Paragraph / Method |
| Cold Bend Test | n/a |