300/500VAC

The new RADOX EN 50306 railway cables are based on the recently developed, halogen-free, electron-beam crosslinked insulation system RADOX EI 306 with the sheath material RADOX EM 104, and comply with the specifications of standard EN 50306 (hazard level: HL3; property level: M).

All cores and cables have tin-plated stranded copper conductors and halogen-free insulation sheaths and materials. The cores and cables are designed for unprotected installation (Class E) or for protected installation (Class P). They are intended for permanent installation in rail vehicles or for applications in which a limited alternating bending stress occurs during service.

  • With voltage rating 300/500 VAC
  • With improved behaviour in case of fire
  • With thin wall isolation

RADOX® EN 50306-2 300V M

RADOX® EN 50306-2 300V M

  • Single core
  • Material designation in accordance with EN 50306-1

RADOX® EN 50306-3 300V MM S

RADOX® EN 50306-3 300V MM S

  • Multi core, screened
  • Insulation and sheathh material designation in accordance with EN 50306-1

RADOX® EN 50306-3 300V MM S

RADOX® EN 50306-3 300V MM S

  • Single core, screened
  • Insulation and sheathh material designation in accordance with EN 50306-1

RADOX® EN 50306-4 1E 300V MM

RADOX® EN 50306-4 1E 300V MM

  • Multi core
  • Insulation and sheathh material designation in accordance with EN 50306-1

RADOX® EN 50306-4 1P 300V MM

RADOX® EN 50306-4 1P 300V MM

  • Multi core
  • Insulation and sheathh material designation in accordance with EN 50306-1

RADOX® EN 50306-4 3E 300V MM S

RADOX® EN 50306-4 3E 300V MM S

  • Multi core, screened
  • Insulation and sheathh material designation in accordance with EN 50306-1

RADOX® EN 50306-4 3P 300V MM S

RADOX® EN 50306-4 3P 300V MM S

The new RADOX® EN 50306 railway cables are based on the recently developed, halogen-free, electron-beam crosslinked insulation system RADOX® EI 306 with the sheathh material RADOX® EM 104, and comply with the specifications of standard EN 50306 (hazard level: HL3; property level: M).

RADOX® EN 50306-4 5E 300V MM S

RADOX® EN 50306-4 5E 300V MM S

The new RADOX® EN 50306 railway cables are based on the recently developed, halogen-free, electron-beam crosslinked insulation system RADOX® EI 306 with the sheathh material RADOX® EM 104, and comply with the specifications of standard EN 50306 (hazard level: HL3; property level: M).

RADOX® EN 50306-4 5P 300V MM S

RADOX® EN 50306-4 5P 300V MM S

The new RADOX® EN 50306 railway cables are based on the recently developed, halogen-free, electron-beam crosslinked insulation system RADOX® EI 306 with the sheathh material RADOX® EM 104, and comply with the specifications of standard EN 50306 (hazard level: HL3; property level: M).