Extra low temperature, extra oil and fuel resistant
Halogen free cables with improved behaviour in case of fire
Easy to strip and flexible
More than 30 years service life with low life cycle costs
How to use it
The cores are intended for fixed installation in railway vehicles. Guidelines for the selection and installation are described in the standards EN 50355 and EN 50343.
Specifications
Voltage rating conductor - earth
600 V AC
Voltage rating conductor - conductor
1000 V AC
Max. permissible voltage rating AC conductor - earth
720 V AC
Max. permissible voltage rating AC conductor - conductor
1200 V AC
Max. permissible voltage rating DC conductor - earth
900 V DC
Max. permissible voltage rating DC conductor - conductor
1500 V DC
Test voltage AC
3500 V AC
Test voltage DC
8400 V DC
Temperature range
-50 °C ... +125°C
Min. bending radius fixed installation (diameter ≤ 12 mm)