Header Image

RF Coaxial Cables

Type SPUMA_400-FR

Description PE Foam - 50 Ohm - double screened (UL AWM Style 1354)
Item number 84040210
2011/65/EC (RoHS) compliant
Halogen Free Yes
2002/96/EC (WEEE) no special marking needed
2000/53/EC (ELV) compliant
Data sheet   SPUMA_400-FR
 

Cable design

SPUMA_400-FR

  Material Detail Diameter
Centre conductor Aluminium / Copper Wire 2.74 mm
Dielectric SPE (Foamed Polyethylene)   7.24 mm
Outer conductor 1 Aluminum / PES longitudinal Foil - 100% coverage 7.40 mm
Outer conductor 2 Copper, Tin plated Braid - 78% coverage 8.15 mm
Jacket LSFH (modified polyethylene) RAL 9005 - bk 10.25
Tolerance of jacket     ± 0.10 mm

Electrical data

Operating Frequency     ≤ 6 GHz
Nom. attenuation Values and graph see below Coefficient a 0.1241
    Coefficient b 0.0080
CW Power Values and graph see below   600 W
Impendance     50 ± 2 Ω 
Capacitance     78 pF/m
Propagation velocity     85 % of c
Signal delay     3.90 ns/m
Insulation resist     > 100000000 MΩm
Test Voltage     3 kVrms
Operating Voltage at sea level   1.60 kVrms
Inner Cond Res DC typical  
4.75 Ω/km
Outer Cond R. DC typical   6.06 Ω/km

General data

Operating Temp min   -40 °C
Operating Temp max   85 °C
Flame propagation Fire Test a UL 1581 § 1100
  Fire Test b UL 1581 § 1090
Halogen Test   IEC 60754
Weight   11.50 kg/100m
Static Bend Radius   25 mm
Repeated Bend Radius   100 mm

Suitable connectors, grounding kits and installation material

Cable Groups
For details contact your nearest HUBER+SUHNER representative
Cable Group U30

Nominal attenuation and power

[GHz] [dB/m] [dB/ft] [W]
0.010.010.006000
0.050.030.012683
0.10.040.011897
0.150.050.021549
0.20.060.021342
0.30.070.021095
0.40.080.02949
0.450.090.03894
0.50.090.03849
0.60.100.03775
0.80.120.04671
0.850.120.04651
0.90.120.04632
0.950.130.04616
10.130.04600
1.80.180.06447
1.90.190.06435
20.190.06424
2.40.210.06387
30.240.07346
40.280.09300
50.320.10268
60.350.11245
 
Please note: Attenuation values at +25°C ambient temperature and sea level * Power values at +40°C ambient temperature and sea level **

Tests

Following tests have been passed successfully. For any details please contact your nearest HUBER+SUHNER representative.
Test description Specification / Paragraph / Method
Cold Bend Test MIL-C-17 § 4.8.19
Smoke Test EN 61034-2
Halogen Test IEC 60754
Fire Test a UL 1581 § 1100
Fire Test b UL 1581 § 1090
Fire Test c IEC 60332-3-24