Header Image

RF Coaxial Cables

Type SPUMA_600

Description PE Foam - 50 Ohm - double screened
Item number 84151738
2011/65/EC (RoHS) compliant
Halogen Free Yes
2002/96/EC (WEEE) no special marking needed
2000/53/EC (ELV) compliant
Data sheet   SPUMA_600
 

Cable design

SPUMA_600

  Material Detail Diameter
Centre conductor Aluminium / Copper Wire 4.44 mm
Dielectric SPE (Foamed Polyethylene)   11.56 mm
Outer conductor 1 Aluminum / PES longitudinal Foil - 100% coverage 11.71 mm
Outer conductor 2 Copper, Tin plated Braid - 78% coverage 12.55 mm
Jacket PE (Polyethylene) RAL 9005 - bk 14.99
Tolerance of jacket     ± 0.25 mm

Electrical data

Operating Frequency     ≤ 6 GHz
Nom. attenuation Values and graph see below Coefficient a 0.0786
    Coefficient b 0.0080
CW Power Values and graph see below   930 W
Impendance     50 ± 2 Ω 
Capacitance     78 pF/m
Propagation velocity     85 % of c
Signal delay     3.90 ns/m
Insulation resist     > 100000000 MΩm
Test Voltage     4 kVrms
Operating Voltage at sea level   2 kVrms
Inner Cond Res DC typical  
1.70 Ω/km
Outer Cond R. DC typical   3.90 Ω/km
PIM
11_N-50-12-20 11_N-50-12-20
 
- 145 dBc

General data

Operating Temp min   -40 °C
Operating Temp max   85 °C
Halogen Test   IEC 60754
Weight   20 kg/100m
Static Bend Radius   38 mm
Repeated Bend Radius   152 mm

Suitable connectors, grounding kits and installation material

Cable Groups
For details contact your nearest HUBER+SUHNER representative
Cable Group X29

Nominal attenuation and power

[GHz] [dB/m] [dB/ft] [W]
0.010.010.009300
0.050.020.014159
0.10.030.012941
0.150.030.012401
0.20.040.012080
0.30.050.011698
0.40.050.021470
0.450.060.021386
0.50.060.021315
0.60.070.021201
0.80.080.021040
0.850.080.021009
0.90.080.02980
0.950.080.03954
10.090.03930
1.80.120.04693
1.90.120.04675
20.130.04658
2.40.140.04600
30.160.05537
40.190.06465
50.220.07416
60.240.07380
 
Please note: Attenuation values at +25°C ambient temperature and sea level * Power values at +40°C ambient temperature and sea level **

Tests

Following tests have been passed successfully. For any details please contact your nearest HUBER+SUHNER representative.
Test description Specification / Paragraph / Method
Halogen Test IEC 60754