Header Image

RF Coaxial Cables

Type SPUMA_500-FR-01

Description PE Foam - 50 Ohm - double screened
Item number 85021564
2011/65/EC (RoHS) compliant
Halogen Free Yes
2002/96/EC (WEEE) no special marking needed
2000/53/EC (ELV) compliant
Data sheet   SPUMA_500-FR-01
 

Cable design

SPUMA_500-FR-01

  Material Detail Diameter
Centre conductor Aluminium / Copper Wire 3.58 mm
Dielectric SPE (Foamed Polyethylene)   9.43 mm
Outer conductor 1 Aluminum / PES longitudinal Foil - 100% coverage 9.55 mm
Outer conductor 2 Copper, Tin plated Braid - 90% coverage 10.36 mm
Jacket LSFH (modified polyethylene) RAL 9005 - bk 12.78
Tolerance of jacket     ± 0.10 mm

Electrical data

Operating Frequency     ≤ 6 GHz
Nom. attenuation Values and graph see below Coefficient a 0.1051
    Coefficient b 0.0059
CW Power Values and graph see below   750 W
Impendance     50 ± 2 Ω 
Capacitance     77.40 pF/m
Propagation velocity     86 % of c
Signal delay     3.87 ns/m
Insulation resist     > 100000000 MΩm
Test Voltage     2 kVrms
Operating Voltage at sea level   1.20 kVrms

General data

Operating Temp min   -40 °C
Operating Temp max   85 °C
Flame propagation Fire Test a EN 60332-1-2
  Fire Test b IEC 60332-3-24
Halogen Test   IEC 60754
Weight   17.80 kg/100m
Static Bend Radius   34 mm
Repeated Bend Radius   130 mm

Suitable connectors, grounding kits and installation material

Cable Groups
For details contact your nearest HUBER+SUHNER representative
Cable Group X31

Nominal attenuation and power

[GHz] [dB/m] [dB/ft] [W]
0.010.010.007500
0.050.020.013354
0.10.030.012372
0.150.040.011936
0.20.050.011677
0.30.060.021369
0.40.070.021186
0.450.070.021118
0.50.080.021061
0.60.080.03968
0.80.100.03839
0.850.100.03813
0.90.110.03791
0.950.110.03769
10.110.03750
1.80.150.05559
1.90.160.05544
20.160.05530
2.40.180.05484
30.200.06433
40.230.07375
50.260.08335
60.290.09306
 
Please note: Attenuation values at +25°C ambient temperature and sea level * Power values at +40°C ambient temperature and sea level **

Tests

Following tests have been passed successfully. For any details please contact your nearest HUBER+SUHNER representative.
Test description Specification / Paragraph / Method
Smoke Test EN 61034-2
Halogen Test IEC 60754
Fire Test a EN 60332-1-2
Fire Test b IEC 60332-3-24