Contacts
ECOC Dublin
ECOC Dublin

As in the former years HUBER+SUHNER will be a part also in 2019 at the ECOC where the latest progress in optical communication technologies will be reported in selected papers, keynotes, presentations and special symposia.

 

23/9/2019 - 25/9/2019
English
We use cookies to improve the website and our services. You accept the use of cookies if you navigate further on this page or close this banner. To find out more, see our data protection statement.

Signal cables

A growing demand of sensors, higher operating temperatures and restricted space are typical in today's motor compartments. These cables have been developed with these specific requirements in mind.

These cables are class D temperature range cables with reduced outer diameter. They have superb resistance to motor oils, fluids and hydrolysis. Thanks to their electron beam cross-linked RADOX® insulation, these cables have excellent resistance to extremes of temperature and abrasion even with reduced outer diameter. Furthermore these RADOX® cables have outstanding electrical characteristics.

The characteristics of these RADOX® cables make them ideal for use in a wide range of applications, where space is at a premium and where cables are subjected to high temperatures. Even high humidity levels and motor vehicle fluids do not negatively affect the lifetime of the cables.

ETFE

ETFE

  • Number of conductors 1
  • Cross section 0.14 to 6 mm2
  • Voltage rating 60/600 V DC
  • Temperature range −55 to +200 °C (3000 h)
  • Min. bending radius 3 × cable dia.

RADOX® 155SFLR

RADOX® 155SFLR

  • Number of conductors 1
  • Cross section 0.35 to 6 mm2
  • Voltage rating 60/600 V DC
  • Temperature range −55 to +150 °C (3000 h)
  • Min. bending radius 3 × cable dia.

RADOX® 155SRW

RADOX® 155SRW

  • Number of conductors 1
  • Cross section 0.14 to 1 mm2
  • Voltage rating 60 V DC
  • Temperature range −55 to +150 °C (3000 h)
  • Min. bending radius 3 × cable dia.

RADOX® Anticapillary (double insulation)

RADOX® Anticapillary (double insulation)

  • Number of conductors 1
  • Cross section 0.35 to 6 mm2
  • Voltage rating 60/600 V DC
  • Temperature range −55 to +150 °C (3000 h)
  • Min. bending radius 3 × cable dia.

RADOX® Anticapillary (single insulation)

RADOX® Anticapillary (single insulation)

  • Number of conductors 1
  • Cross section 0.35 to 10 mm2
  • Voltage rating 60/600 V DC
  • Temperature range −55 to +150 °C (3000 h)
  • Min. bending radius 3 × cable dia.

Contact
HUBER+SUHNER Inc.
Customer Service
Customer Service
  +1 866 482 3778
  +1 704 587 1238