Extra low temperature, extra oil and fuel resistant
Halogen free, electron-beam cross-linked cables with improved behaviour in case of fire
Ozone, weather and UV resistant
Easy to strip, soldering iron resistant and flexible
More than 30 years service life with low life cycle costs
How to use it
The cables are intended for permanent installation in rail vehicles or for applications in which a limited alternating bending stress occur during service. Guidelines for selection and installation are described in the standards EN 50355 and EN 50343.
Specifications
Voltage rating conductor - earth
3600 V AC
Voltage rating conductor - conductor
6000 V AC
Max. permissible voltage rating AC conductor - earth
4300 V AC
Max. permissible voltage rating AC conductor - conductor
7200 V AC
Max. permissible voltage rating DC conductor - earth
5400 V DC
Max. permissible voltage rating DC conductor - conductor
9000 V DC
Test voltage AC
11000 V AC
Test voltage DC
26000 V DC
Temperature range
-50 °C ... +125°C
Min. bending radius fixed installation (diameter ≤ 12 mm)
3 x D
Min. bending radius fixed installation (diameter > 12 mm)
4 x D
Min. bending radius sporadic movement (diameter ≤ 12 mm)
4 x D
Min. bending radius sporadic movement (diameter > 12 mm)